Bedside SpO2 patientes Cras System pro neonate
Product attributa
EXEMPLUM | Bedside SpO2 Patient Cras System \ NICU\ICU |
Categoria | Bedside SpO2 patientes Cras System pro neonate |
Series | narigmed®BTO-100CXX |
sarcina | 1pcs/arca, 8box/carton |
Propono genus | 5.0 inch LCD |
Propono parametri | SPO2\PR\PI\RR |
SpO2 range mensurae | 35%~100% |
SpO2 measurement Accuracy | ±2%(70%~100%) |
PR measurement range | 30~250bpm |
PR measurement Accuracy | Maior e ± 2bpm et ± 2% |
Anti- motus perficientur | SpO2±3% PR±4bpm |
Humilis perfusio perficiendi | SPO2±2%, PR±2bpm |
Coepi output tempus / mensurae tempus | 4s |
humilis perfusio sustineri potest saltem | 0.093% |
Humilis perfusio perficiendi | SPO2±2%, PR±2bpm |
perfusio Index Range | 0.02%~20% |
Rate respiratorii | 4rpm~70rpm |
Terror administratione systematis | ETIAM' |
Specillum stilla deprehensio | ETIAM' |
historica trend notitia | ETIAM' |
Unus click ad terrorem averte | ETIAM' |
Genus patientes estote procuratio | ETIAM' |
Idoneam Homines | Idoneum pro plus quam 1Kg neonatum VEL adultum |
Typical potentia consummatio | <40mA |
Ponderibus | 803g (per sacculum) |
Dismension | 26.5cm*16.8cm*9.1cm |
Product Status | Self-exculta products |
Voltage - Supple | Type-C 5V vel Lithium altilium potentia copia |
Temperature operating | 5°C ~ 40°C XV% ~ XCV% (humiditas) 50kPa~ 107.4kPa |
repono environment | -20°C ~ 55°C XV% ~ XCV% (humiditas) 50kPa~ 107.4kPa
|
Post Features
1. Functiones comprehensivae: Metiri potest clavem indicibus physiologicis ut satietatem sanguinis oxygeni (Spo2), rate pulsus (PR), rate respiratorii (RR) et perfusionis index parametri (PI) fœtorum.
2. Lata cor rate range: subsidia mensurae visibilis cordis ultra- latis et aptat ad varias notas celeritatis cordis ambigua natorum.
3. Usus universalis pro manibus et pedibus: Utrum manus sit vel pedes, accurate metiri potest, solvendo problema fœtus cum circulatione pauperum peripheralium et debilium significationibus.
4. Specimen speciale et optimae algorithmus: Per algorithmum programmatum speciatim designatum et adaptans, etiam in casu sanguinis pauperis circulatio et perfusio in fœtuum insufficiens, signa efficaciter capi possunt et discursum esse ut variae res clare exponi possint. Mensurata pretii.
In summa, notam oximetris neonatalis in lectis Narigmed accuratam et certam vigilantiam parametri physiologicae neonatales in occasus clinicis, praesertim in casibus neonatis cum volubili sanguinis circulatione vel humili perfusione, praebere potest.